Lug-Type High-Performance Butterfly Valve

Lug-Type High-Performance Butterfly Valve

Details
The Lug-Type High-Performance Butterfly Valve incorporates a double-offset eccentric structure to provide bi-directional tight shut-off and precise throttling control in piping systems. Built with threaded bolt lugs conforming to standard flange dimensions, this valve enables downstream piping maintenance under full operating pressure. Available in sizes from 2" to 48" with pressure ratings up to Class 600, it delivers low operational friction, extended seat durability, and zero-leakage performance.
Category
High-Performance Butterfly Valves
 
Send Inquiry
Description
Technical Parameters

The Lug-Type High-Performance Butterfly Valve incorporates a double-offset eccentric structure to provide bi-directional tight shut-off and precise throttling control in piping systems. Built with threaded bolt lugs conforming to standard flange dimensions, this valve enables downstream piping maintenance under full operating pressure. Available in sizes from 2" to 48" with pressure ratings up to Class 600, it delivers low operational friction, extended seat durability, and zero-leakage performance.

 

Key Features

 

Double-Offset Shaft Design: Reduces friction between the disc and seat during movement, minimizing operating torque and extending seal longevity.


Bi-Directional Zero-Leakage Sealing: Achieves Class VI bubble-tight shut-off across fluid flow directions.


Dead-End Isolation Capability: Threaded lugs permit downstream flange removal while maintaining full line pressure upstream.


ISO 5211 Direct Mounting: Allows direct installation of pneumatic, electric, or manual actuators without mounting kit clearance issues.


Fugitive Emission Control: Live-loaded stem packing prevents external media leakage during high-frequency thermal cycling.

 

Design & Construction

 

Body Configuration: Fully tapped lugs align with standard flange bolt patterns for sandwiched or end-of-line installation.


Eccentric Geometry: The primary offset places the stem behind the sealing surface; the secondary offset positions the stem away from the pipe axis.


Internal Disc Travel Stop: Cast-in mechanical stop prevents seat distortion caused by disc over-travel.


Anti-Blowout Shaft Mechanism: Retaining ring and internal shoulder design satisfy API 609 safety standards to retain the stem under internal line pressure.

 

Working Principle

 

The double-offset disc rotates 90 degrees on two displaced axes. When opening begins, the disc cams away from the seat ring immediately upon rotation. This movement clears contact along the entire sealing boundary within the first few degrees of stroke, eliminating friction during continuous travel and maintaining seat profile integrity.

 

Technical Specifications

 

Parameter

Standard Value

Size Range

2" – 48" (DN50 – DN1200)

Pressure Class

ASME Class 150 / 300 / 600, PN16 / 25 / 40

Temperature Range

-29°C to 230°C (Soft Seat) / -50°C to 450°C (Metal Seat)

Leakage Class

ANSI FCI 70-2 Class VI / ISO 5208 Rate A

Design Standard

API 609, ASME B16.34

Face-to-Face Standard

API 609 Category B, ISO 5752

Flange Connection

ASME B16.5, EN 1092-1

Testing Standard

API 598, ISO 5208

Actuator Top Flange

ISO 5211

 

Materials & Trim Options

 

Component

Standard Configuration

Severe Service Option

Body

ASTM A216 WCB

ASTM A351 CF8M, Duplex 2205, Super Duplex 2507

Disc

ASTM A351 CF8M

Monel 400, Hastelloy C276, 17-4PH

Shaft

17-4PH (UNS S17400)

Duplex 2205, Inconel 718

Seat Ring

RTFE (Reinforced PTFE)

Stainless Steel 316 + Flexible Graphite

Packing

Flexible Graphite

PTFE V-Ring / Live-Loaded Graphite

Bearing Bushing

PTFE-Lined SS316

Nitrided SS316

 

End Connection / Configuration

 

Full-Tapped Lugs: Threaded holes align with ASME B16.5 and EN 1092-1 bolt specifications.


End-of-Line Rating: Certified for full differential pressure service without requiring a downstream mating flange.


Precision Alignment Lugs: Cast body guides ensure exact positioning between line flanges.

 

Operation & Actuation

 

Manual Control: Lever operators with locking notch plates for sizes 2" to 6"; enclosed worm gear operators for sizes 8" and larger.


Pneumatic Actuation: Double-acting or spring-return rack-and-pinion actuators fitted with limit switch boxes and positioners.


Electric Actuation: Multi-turn or quarter-turn electric drives with manual overrides and weather-proof enclosures.

 

Applicable Standards

 

Valve Construction

API 609, ASME B16.34

Face-to-Face Dimensions

API 609, ISO 5752, ASME B16.10

Flange Dimensions

ASME B16.5, EN 1092-1

Inspection & Pressure Testing

API 598, ISO 5208

Fire Safety Standard

API 607 / ISO 10497

Actuator Mounting

ISO 5211

Fugitive Emissions Control

ISO 15848-1, API 641

 

Applications

 

Chemical Processing: Controls flow of organic acids, solvents, and neutral liquid lines.


Water & Wastewater Treatment: Manages raw water filtration, chemical dosing, and pump isolation.


HVAC Infrastructure: Regulates chilled water distribution and cooling tower circulation loops.


Power Generation Facilities: Handles steam condensate, cooling water, and auxiliary isolation systems.


Pulp & Paper Processing: Regulates process water treatment and white liquor transfer lines.

 

Product Selection Guide

 

Operating Conditions Check: Select RTFE seats for service temperatures under 230°C. Specify metal seats for high-temperature lines or fire-safe process zones.


Material Compatibility: Match Carbon Steel (WCB) bodies to non-corrosive media; specify Stainless Steel (CF8M) or Duplex alloys for corrosive fluids or marine exposure.


Actuator Sizing Calculation: Add a minimum 25% to 30% safety cushion to standard torque figures when selecting actuators for high-viscosity or high-differential-pressure service.


End-of-Line Verification: Confirm that full lug pressure ratings match total pipeline working pressure when planning dead-end installation configurations.

 

Inspection & Testing

 

Hydrostatic Shell Test: Tested at 1.5 times nominal pressure rating per API 598 requirements.


Seat Leakage Test: High-pressure hydrostatic testing and low-pressure pneumatic seat testing at 80 psi (5.5 bar) per ISO 5208.


Dimensional Verification: Critical body, stem, and flange face dimensions checked using calibrated instruments.


Material Traceability: Positive Material Identification (PMI) testing conducted on alloy components; EN 10204 3.1 inspection certificates supplied for pressure-retaining parts.

 

Customization / OEM

 

Corrosion-Resistant Alloys: Castings available in Titanium, Monel, Hastelloy, and Nickel Aluminium Bronze.


Stem Extensions: Extended shafts supplied for insulated lines or cryogenic operating conditions.


Surface Coatings: External options include high-build epoxy, polyurethane, or custom fluoropolymer linings.


Private Labeling Service: Custom nameplate laser-marking, cast body identification, and specialized packaging for distribution networks.

 

Technical Documents

 

Technical Data Sheet (PDF) - Contains pressure-temperature curves, torque values, and detailed dimensions.


2D General Arrangement Drawings (DWG / PDF) - Provides outline dimensions, flange alignment specs, and actuator interface details.


3D CAD Models (STEP / IGES) - Standard models available for engineering design integration.


IOM Manual (PDF) - Complete installation steps, flange bolt tightening sequences, and maintenance guidelines.

 

FAQ

 

Q: What is the primary difference between a lug-type body and a wafer-type body?

A: A lug-type body contains threaded holes matching flange bolt circles, allowing attachment from either side with individual bolts. This design permits downstream piping disconnection while keeping upstream pressure fully contained. A wafer body relies on long through-bolts clamping the valve between two flanges, preventing line disassembly without complete system shutdown.

Q: How does the double-offset geometry reduce internal wear?

A: The double-offset shaft placement shifts the stem off the valve center and behind the seal face. During opening, the disc cams away from the seat ring within the first few degrees of rotation, eliminating continuous sliding friction across the remainder of the stroke.

Q: Is this valve suitable for service involving small solid particles?

A: For lines containing light suspended solids, soft RTFE seats with reinforced edge profiles are recommended. For higher solid concentrations or mild slurries, hardened metal seat options provide resistance against surface scoring.

Q: How do temperature requirements determine seat material selection?

A: Reinforced PTFE seats provide Class VI sealing at operating temperatures up to 230°C. For temperatures exceeding 230°C or applications requiring API 607 fire-safe compliance, metal-to-metal seating systems are selected.

Q: What safety factor should be applied to actuator torque calculations?

A: Apply a safety factor of 25% to 30% above the published base operating torque to accommodate line pressure surges, fluid viscosity variations, or extended inactive periods.

 

Hot Tags: lug-type high-performance butterfly valve, China lug-type high-performance butterfly valve manufacturers, suppliers, factory, API Triple Offset Flanged Butterfly Valve, PFA lined butterfly valve, pneumatic lug butterfly valve, regulating butterfly valve, single offset butterfly valve, wafer rubber seated butterfly valve

Send Inquiry
Contact usif have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!